12 KiB
Calibration
Here, we explain how to use the calibration tools with TUM-VI, EuRoC, UZH-FPV and Kalibr datasets as an example.
TUM-VI dataset
Download the datasets for camera and camera-IMU calibration:
mkdir ~/tumvi_calib_data
cd ~/tumvi_calib_data
wget http://vision.in.tum.de/tumvi/calibrated/512_16/dataset-calib-cam3_512_16.bag
wget http://vision.in.tum.de/tumvi/calibrated/512_16/dataset-calib-imu1_512_16.bag
Camera calibration
Run the camera calibration:
basalt_calibrate --dataset-path ~/tumvi_calib_data/dataset-calib-cam3_512_16.bag --dataset-type bag --aprilgrid /usr/etc/basalt/aprilgrid_6x6.json --result-path ~/tumvi_calib_result/ --cam-types ds ds
The command line options have the following meaning:
--dataset-pathpath to the dataset.--dataset-typetype of the datset. Currently onlybagandeurocformats of the datasets are supported.--result-pathpath to the folder where the resulting calibration and intermediate results will be stored.--aprilgridpath to the configuration file for the aprilgrid.--cam-typescamera models for the image streams in the dataset. For more details see arXiv:1807.08957.
After that, you should see the calibration GUI:

The buttons in the GUI are located in the order which you should follow to calibrate the camera. After pressing a button the system will print the output to the command line:
load_datasetloads the dataset.detect_cornersstarts corner detection in the background thread. Since it is the most time consuming part of the calibration process, the detected corners are cached and loaded if you run the executable again pointing to the same result folder path.init_cam_intrcomputes an initial guess for camera intrinsics.init_cam_posescomputes an initial guess for camera poses given the current intrinsics.init_cam_extrcomputes an initial transformation between the cameras.init_optinitializes optimization and shows the projected points given the current calibration and camera poses.optimizeruns an iteration of the optimization and visualizes the result. You should press this button until the error printed in the console output stops decreasing and the optimization converges. Alternatively, you can use theopt_until_convergecheckbox that will run the optimization until it converges automatically.save_calibsaves the current calibration ascalibration.jsonin the result folder.compute_vign(Experimental) computes a radially-symmetric vignetting for the cameras. For the algorithm to work, the calibration pattern should be static (camera moving around it) and have a constant lighting throughout the calibration sequence. If you runcompute_vignyou should presssave_calibafterwards. The png images with vignetting will also be stored in the result folder.
You can also control the process using the following buttons:
show_frameslider to switch between the frames in the sequence.show_cornerstoggles the visibility of the detected corners shown in red.show_corners_rejectedtoggles the visibility of rejected corners. Works only whenshow_cornersis enabled.show_init_reprojshows the initial reprojections computed by theinit_cam_posesstep.show_optshows reprojected corners with the current estimate of the intrinsics and poses.show_vigntoggles the visibility of the points used for vignetting estimation. The points are distributed across white areas of the pattern.show_idstoggles the ID visualization for every point.huber_threshcontrols the threshold for the huber norm in pixels for the optimization.opt_intrcontrols if the optimization can change the intrinsics. For some datasets it might be helpful to disable this option for several first iterations of the optimization.opt_until_convergeruns the optimization until convergence.stop_threshdefines the stopping criteria. Optimization will stop when the maximum increment is smaller than this value.
Camera + IMU + Mocap calibration
After calibrating the camera you can run the camera + IMU + Mocap calibration. The result path should point to the same folder as before:
basalt_calibrate_imu --dataset-path ~/tumvi_calib_data/dataset-calib-imu1_512_16.bag --dataset-type bag --aprilgrid /usr/etc/basalt/aprilgrid_6x6.json --result-path ~/tumvi_calib_result/ --gyro-noise-std 0.000282 --accel-noise-std 0.016 --gyro-bias-std 0.0001 --accel-bias-std 0.001
The command line options for the IMU noise are continous-time and defined as in Kalibr:
--gyro-noise-stdgyroscope white noise.--accel-noise-stdaccelerometer white noise.--gyro-bias-stdgyroscope random walk.--accel-bias-stdaccelerometer random walk.
The buttons in the GUI are located in the order which you need to follow to calibrate the camera-IMU setup:
load_dataset,detect_corners,init_cam_posessame as above.init_cam_imuinitializes the rotation between camera and IMU by aligning rotation velocities of the camera to the gyro data.init_optinitializes the optimization. Shows reprojected corners in magenta and the estimated values from the spline as solid lines below.optimizeruns an iteration of the optimization. You should press it several times until convergence before proceeding to next steps. Alternatively, you can use theopt_until_convergecheckbox that will run the optimization until it converges automatically.init_mocapinitializes the transformation from the Aprilgrid calibration pattern to the Mocap coordinate system.save_calibsave the current calibration ascalibration.jsonin the result folder.save_mocap_calibsave the current Mocap to IMU calibration asmocap_calibration.jsonin the result folder.
You can also control the visualization using the following buttons:
show_frame-show_idsthe same as above.show_splinetoggles the visibility of enabled measurements (accel, gyro, position, velocity) generated from the spline that we optimize.show_datatoggles the visibility of raw data contained in the dataset.show_accelshows accelerometer data.show_gyroshows gyroscope data.show_posshows spline position forshow_splineand positions generated from camera pose initialization transformed into IMU coordinate frame forshow_data.show_rot_errorshows the rotation error between spline and camera pose initializations transformed into IMU coordinate frame.show_mocapshows the mocap marker position transformed to the IMU frame.show_mocap_rot_errorshows rotation between the spline and Mocap measurements.show_mocap_rot_velshows the rotation velocity computed from the Mocap.
The following options control the optimization process:
opt_intrenables optimization of intrinsics. Usually should be disabled for the camera-IMU calibration.opt_posesenables optimization based camera pose initialization. Sometimes helps to better initialize the spline before running optimization withopt_corners.opt_cornersenables optimization based on reprojection corner positions (should be used by default).opt_cam_time_offsetcomputes the time offset between camera and the IMU. This option should be used only for refinement when the optimization already converged.opt_imu_scaleenables IMU axis scaling, rotation and misalignment calibration. This option should be used only for refinement when the optimization already converged.opt_mocapenables Mocap optimization. You should run it only after pressinginit_mocap.huber_threshcontrols the threshold for the huber norm in pixels for the optimization.opt_until_convgruns the optimization until convergence.stop_threshdefines the stopping criteria. Optimization will stop when the maximum increment is smaller than this value.
NOTE: In this case we use a pre-calibrated sequence, so most of refinements or Mocap to IMU calibration will not have any visible effect. If you want to test this functionality use the "raw" sequences, for example http://vision.in.tum.de/tumvi/raw/dataset-calib-cam3.bag and http://vision.in.tum.de/tumvi/raw/dataset-calib-imu1.bag.
EuRoC dataset
Download the datasets for camera and camera-IMU calibration:
mkdir ~/euroc_calib_data
cd ~/euroc_calib_data
wget http://robotics.ethz.ch/~asl-datasets/ijrr_euroc_mav_dataset/calibration_datasets/cam_april/cam_april.bag
wget http://robotics.ethz.ch/~asl-datasets/ijrr_euroc_mav_dataset/calibration_datasets/imu_april/imu_april.bag
Camera calibration
Run the camera calibration:
basalt_calibrate --dataset-path ~/euroc_calib_data/cam_april.bag --dataset-type bag --aprilgrid /usr/etc/basalt/aprilgrid_6x6.json --result-path ~/euroc_calib_result/ --cam-types ds ds
Camera + IMU calibration
After calibrating the camera you can run the camera + IMU calibration. The result-path should point to the same folder as before:
basalt_calibrate_imu --dataset-path ~/euroc_calib_data/imu_april.bag --dataset-type bag --aprilgrid /usr/etc/basalt/aprilgrid_6x6.json --result-path ~/euroc_calib_result/ --gyro-noise-std 0.000282 --accel-noise-std 0.016 --gyro-bias-std 0.0001 --accel-bias-std 0.001
UZH dataset
Download the datasets for camera and camera-IMU calibration:
mkdir ~/uzh_calib_data
cd ~/uzh_calib_data
wget http://rpg.ifi.uzh.ch/datasets/uzh-fpv/calib/indoor_forward_calib_snapdragon_cam.bag
wget http://rpg.ifi.uzh.ch/datasets/uzh-fpv/calib/indoor_forward_calib_snapdragon_imu.bag
Camera calibration
Run the camera calibration:
basalt_calibrate --dataset-path ~/uzh_calib_data/indoor_forward_calib_snapdragon_cam.bag --dataset-type bag --aprilgrid /usr/etc/basalt/aprilgrid_5x4_uzh.json --result-path ~/uzh_calib_result/ --cam-types ds ds
Camera + IMU calibration
After calibrating the camera you can run the camera + IMU calibration. The result-path should point to the same folder as before:
basalt_calibrate_imu --dataset-path ~/uzh_calib_data/indoor_forward_calib_snapdragon_imu.bag --dataset-type bag --aprilgrid /usr/etc/basalt/aprilgrid_5x4_uzh.json --result-path ~/uzh_calib_result/ --gyro-noise-std 0.05 --accel-noise-std 0.1 --gyro-bias-std 4e-5 --accel-bias-std 0.002
Kalibr dataset
Download the datasets for camera and camera-IMU calibration from here (Sample datasets):
mkdir ~/kalibr_calib_data
cd ~/kalibr_calib_data
# Download data
tar xvf static.tar.gz
tar xvf dynamic.tar.gz
Camera calibration
Run the camera calibration:
basalt_calibrate --dataset-path ~/kalibr_calib_data/static/static.bag --dataset-type bag --aprilgrid /usr/etc/basalt/aprilgrid_6x6.json --result-path ~/kalibr_calib_result/ --cam-types ds ds ds ds
Camera + IMU calibration
After calibrating the camera you can run the camera + IMU calibration. The result-path should point to the same folder as before:
basalt_calibrate_imu --dataset-path ~/kalibr_calib_data/dynamic/dynamic.bag --dataset-type bag --aprilgrid /usr/etc/basalt/aprilgrid_6x6.json --result-path ~/kalibr_calib_result/ --gyro-noise-std 0.005 --accel-noise-std 0.01 --gyro-bias-std 4.0e-06 --accel-bias-std 0.0002